Skip to Main Content

Ansys EMC Plus
Platform-Level EMC Cable Modeling

Electromagnetic modeling and simulation software.

Platform-Level EMC Cable Modeling and Simulation Software

Ansys EMC Plus specializes in analyzing lightning-induced electromagnetic (EM) effects on large platforms as well as cable EMI/EMC problems in aircraft and automobile platforms to support EMC certification. Ansys EMC Plus bolsters the design-to-validation workflow with system-design evaluation for cable harness models in the aerospace, automotive, military, oil and gas, consumer electronics and energy sectors.

  • Check icon outline
    SpaceClaim’s Direct Modeler UI
  • Check icon outline
    Cable Cross-Sections Electrostatic Simulation
  • Check icon outline
    Streamlined Cable-Focused Workflow
  • Check icon outline
    Hybrid Transmission Line Harness

Product Specs

Ansys EMC Plus simulates issues including EMI/EMC for cables, crosstalk, shielding effectiveness, lightning strikes, High Intensity Radiated Fields (HIRF) and Electromagnetic Pulse (EMP). These solutions will provide great cost benefits for companies in their design, validation and certification programs.

  • Finite-Difference-Time-Domain (FDTD)
  • Hybrid Transmission Line Solve
  • Supports Ansys HPC
  • Supports Multilevel Shielding
  • Inductance and Capacitance Simulation
  • Ansys SpaceClaimTM Included
  • Thin-Surface Algorithms
  • Ansys HFSS Integration

Aerospace and Automotive Electromagnetic Test Environments

Test Electromagnetic Compatibility (EMC) of Complex Aircraft and Automobiles Systems with a Full Electromagnetic (EM) Model.

EMA3D Cable

To assess vulnerability to lightning strikes, aviation engineers have to understand the specific lightning environment for the aircraft.

A manufacturer of civilian and military aircraft used Ansys EMC Plus to improve their understanding of aircraft system lightning response and validate a numerical approach to compliance that compared full aircraft simulations to full physical lightning transient analysis (LTA) tests.

January 2023

What's New

Integrations with multiple Ansys tools (Discovery, Fluent, STK, and many more) support a wide range of computational Multiphysics applications and enhanced support for EMC design work and a new Cable Harness tool among the plethora of new capabilities in the Ansys EMC Plus.

API and interoperability with Ansys
API & Interoperability

New API and interoperability features with Ansys optiSLang, Ansys ModelCenter, Ansys STK, or a user Python script (pyEMA3D.) This feature allows 3D geometry and cables to be programmatically adjusted and the simulation re-run many times without user interaction.

Automated Workflows
Automated Workflows

New automated workflows enable full-device and full-vehicle simulation with automatic material assignment from Ansys Granta, automatic meshing, and automatic post-processing with standard electromagnetic compatibility (EMC) limit curves.

Multiple Cable Harness
Multiple Cable Harness

A new Multiple Cable Harness Tool permits the automatic import of additional cable database formats, the joining of different harnesses at connectors, and the rapid assignment of cable termination circuit elements.

EMA3D CABLE CAPABILITIES

Simulate System-Level Cable Electromagnetic Compatibility (EMC) and Real-World EMI Events

When you’re designing the wiring harness for the controls system of a helicopter or the power distribution system of a next generation electric vehicle (EV), unwanted electromagnetic system effects can drastically uphold long-term production and cost-effectiveness.

As systems increase in complexity, system-level simulation becomes increasingly crucial to properly design an EMC solution and mitigate design failure in the future. EMA3D boasts many capabilities that can help validate your design of a single cable assembly, the high-level system, and every system in between.

2020-12-system-level-emc-simulation.jpg

Key Features

不必要的内部和外部coupling can prevent or inhibit testing certifications. Ansys EMC Plus’s capabilities start with:

  • Shielding effectiveness analysis
  • High Intensity Radiated Fields (HIRF) and cable coupling
  • EMI crosstalk between cables
  • Current return network optimization
  • Cable signal integrity
  • Lightning and EMP coupling to equipment interfaces

Radiated emissions simulations can be performed in full platforms, allowing the users to compute electric and magnetic fields anywhere in space due to radiation from cables and components. The automated coupling toHFSSallows engineers to consider the radiation of high-fidelity components such as packages, PCBs and antennas.

The coupling from ideal sources or specific components to cables installed in realistic platforms can be easily computed in the simulation environment. Radiated immunity tests, such as High Intensity Radiated Fields (HIRF) or Electromagnetic Pulse (EMP), can be easily simulated in Ansys EMC Plus.

Easily setup Bulk Current Injection (BCI) and conduct susceptibility tests on wiring harness bundles.

By using a very forgiving mesh, Ansys EMC Plus can handle extremely complex platforms to compute shielding effectiveness.

Compute induced voltage and currents on real wiring harness bundles using the transmission line solver.

Evaluate how the digital and analog signals are affected by the cable definition and external electromagnetic noise.

EMA3D CABLE RESOURCES & EVENTS

Featured Webinars

Webinar on Demand
null
Part 2: Electromagnetic Certification (EMC)

The unique capabilities of EMA3D tools are brought to bear along with other Ansys tools to collaboratively optimize EMC for electronic designs.

Webinar On Demand
null
Part 4: EMI and ESD Simulation of an Entire Electronic Device

This webinar, the 4th in a 5-part series, explores the use of EMA3D tools in conjunction with other Ansys computational electromagnetic simulation tools for modeling and simulating EMI effects in entire electronic systems.



Ansys software is accessible

It's vital to Ansys that all users, including those with disabilities, can access our products. As such, we endeavor to follow accessibility requirements based on the US Access Board (Section 508), Web Content Accessibility Guidelines (WCAG), and the current format of the Voluntary Product Accessibility Template (VPAT).

Découvrez ce qu'Ansys peut faire pour vous

Contactez-nous aujourd'hui

* = Champ requis

Merci de nous contacter !

We’re here to answer your questions and look forward to speaking with you. A member of our Ansys sales team will contact you shortly.

Image de pied de page